DC/AC Resistive Inductive Dummy Load Bank 100kw 200kw 500kw for UPS Generator Testing

Product Details
Customization: Available
After-sales Service: 1 Year
Application: Diesel Generator
Still deciding? Get samples of US$ 3000/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 4 staff(s) with over 6 years of overseas trading experience
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (18)
  • DC/AC Resistive Inductive Dummy Load Bank 100kw 200kw 500kw for UPS Generator Testing
  • DC/AC Resistive Inductive Dummy Load Bank 100kw 200kw 500kw for UPS Generator Testing
  • DC/AC Resistive Inductive Dummy Load Bank 100kw 200kw 500kw for UPS Generator Testing
  • DC/AC Resistive Inductive Dummy Load Bank 100kw 200kw 500kw for UPS Generator Testing
  • DC/AC Resistive Inductive Dummy Load Bank 100kw 200kw 500kw for UPS Generator Testing
  • DC/AC Resistive Inductive Dummy Load Bank 100kw 200kw 500kw for UPS Generator Testing
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • Our Customers
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
AC400-200kw
Power
200kw
Model
AC400-200kw
Language
English
Structure
Canopy & Wheels
Color&Logo
Customized
Usage
Diesel Generator or UPS,Data Center
Electronics
Abbschneider
Warranty
1 Year
Transport Package
Plywood Case
Specification
3CBM
Trademark
NEWTEC
Origin
China

Packaging & Delivery

Package Size
230.00cm * 150.00cm * 160.00cm
Package Gross Weight
700.000kg

Product Description

Product Description

AC400-200kw Automatic Load Bank

 
Foreword This solution introduces AC400-200kw Automatic Load Bank and its accessories, including their function, performance, usage, providing users with a high efficient and reliable choice to test generator.
All the pictures quoted in this agreement are for reference only.
 
Testing System We do not supply generator, power cable, PC and printer if not specified. DC/AC Resistive Inductive Dummy Load Bank 100kw 200kw 500kw for UPS Generator Testing
  1. Supply List
The following form presents the accessories provided when we make shipment.
Items Quantity Remark
AC400-200kw Automatic Load Bank 1 sets  
Power Cord 1 3 meters  
RS485 1 50 meters
RS485/RS232/USB Converter 1  
Documents accompanied with shipment Quantity Remark
Operation Instruction 2  
Certification 1  
Warranty Card 1 12 months
Packing List 1  
Receiving Apron 1  
Data Managing Software U-disk 1  
Testing Report 1  
 
Technical Parameter
  Technical Parameter  
Rating voltage/frequency 400VAC power 200kw; 3 phase 4 wire, 60Hz
Max Load Power 200kw
Load Steps 1, 2, 2, 5, 10, 10, 20, 50, 100, 200kw, total 200kw.
Power Factor 1
Load Tolerance  (each step) ±5%
Load Tolerance (overall) ±3%
Display Meter Multiple function meter 
Fan Control Power   External power 400VAC 3 phase 4 wire 60Hz
Wire Connection   Load bank input--busbar (star coupling "Y") Control power input--terminal block
Communication Interface RS232/RS485
Insulation F
Way of Working Continuous Working
Cooling Forced air, horizontal air intake and upwards exhaust cooling  
Transportation With lifting eyes and wheel castors  
Color As customer's requirements or as our design
Dimensions For 200kw load bank: 2300*1250*1680mm (L*W*H)
Weight About 700kgs
  Operating Environment Parameter
Ambient Temperature -10°C~+50°C
Relative Humidity ≤95%
Atmospheric Pressure 86~106kPa
  Brands of Main Components
Contactor ABBSchneider
Fuse MIRO
PLC Siemens
Alloy Resistor (self-developing)
Data Processing Software  (self-developing)
 
Functions
  1. 3 line LED multi-function meter can display real-time voltage and current of three phase and each phase, resistive power, power factor, apparent power, frequency and running time of generating set.
  2. User can pre-set the power then press the master load button.
  3. Control mode: user can choose local control or intelligent control (through PC)
  4. Control mode interlock: there is switch in control panel to choose control mode, other control mode is invalid if user choose one control mode.
  5. Protection
  6. Have emergency stop button.
  7. In case of over-load, over-heat, short circuit, load bank will automatically remove load and give alarm.
  8. Fan protection: Load bank could not load before power of fan is on.  
  9. Give alarm when any fan is abnormal or with insufficient air volume, etc.
  10. Protection button: there are some protection buttons can be switched off when false alarm or for special requirements.
 
Data Processing Software  
  1. Automatic load: User can set several periods of power and duration and in turn of 
0%→25%→50%→75%→100% or 110% then →75%→50%→25%→0%.etc to make automatic load testing.
  1. Can make parallel testing for several units.
  2. Data can be saved, could display real-time data and history data.
  3. Charts and graphs can be exported in format of JPG while testing data exported in Excel and Word format, and all can be printed. Load Bank Pictures
DC/AC Resistive Inductive Dummy Load Bank 100kw 200kw 500kw for UPS Generator TestingDC/AC Resistive Inductive Dummy Load Bank 100kw 200kw 500kw for UPS Generator TestingDC/AC Resistive Inductive Dummy Load Bank 100kw 200kw 500kw for UPS Generator TestingDC/AC Resistive Inductive Dummy Load Bank 100kw 200kw 500kw for UPS Generator Testing
Company Profile

 

DC/AC Resistive Inductive Dummy Load Bank 100kw 200kw 500kw for UPS Generator TestingNewtec Power Equipment Co.,Ltd is one of the leading and largest world-wide producers and exporters for Diesel Generator (land diesel power generator&marine diesel generating set) and Gasoline Generator set from 1kva up to 2500kva. Transformed from a state owned enterprise and founded in 2005, Newtec's Factory and generators assembling centers have more than two decades of experience in the design, research and manufacturing of diesel genset in strict compliance with ISO and CE standards. Up to being now, more than 20,000 sets of high quality generaotr set from Newtec Power have been working well in many fields including railways, oil fields, Schools, hospitals, banks, supermarkets, industries, tall buildings, sea ports and bases etc.
DC/AC Resistive Inductive Dummy Load Bank 100kw 200kw 500kw for UPS Generator TestingDC/AC Resistive Inductive Dummy Load Bank 100kw 200kw 500kw for UPS Generator TestingDC/AC Resistive Inductive Dummy Load Bank 100kw 200kw 500kw for UPS Generator Testing
Our Customers

 

DC/AC Resistive Inductive Dummy Load Bank 100kw 200kw 500kw for UPS Generator Testing
Packaging & Shipping

 

DC/AC Resistive Inductive Dummy Load Bank 100kw 200kw 500kw for UPS Generator Testing
FAQ

 

1.Q: What is your MOQ of this item?
A:1 Set

2.Q: What is the lead time?
A:7 working days after received the 30%T/T deposit

3.Q: Is it all right to make customer's own brand name?
A:We can be your OEM manufacture with your authorization of brand.

4.Q: Where is your Loading Port?
A:Shanghai or others

5.Q: What are your payment terms?
A:30% TT as deposit,70% TT before Shipment.

6.Q: What is your company's available production capacity?
A:100 Sets per month

7.Q:What's the warranty time of diesel generators?
A:12 Months or 1000 working hours


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier